6QT3

Radiation damage study on a 16mer DNA segment, structure at 12.0 MGy dose

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I24
Synchrotron siteDiamond
BeamlineI24
Temperature [K]100
Detector technologyPIXEL
Collection date2018-10-22
DetectorDECTRIS PILATUS3 6M
Wavelength(s)0.9686
Spacegroup nameH 3 2
Unit cell lengths36.888, 36.888, 162.203
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution31.360 - 1.800
R-factor0.2255
Rwork0.222
R-free0.29140
Structure solution methodFOURIER SYNTHESIS
Starting model (for MR)6qt1
RMSD bond length0.009
RMSD bond angle1.670
Data reduction softwareDIALS
Data scaling softwareAimless (0.7.3)
Phasing softwareMOLREP
Refinement softwareREFMAC (5.8.0238)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]31.36031.3401.850
High resolution limit [Å]1.8007.8401.800
Rmerge0.0590.0282.821
Rmeas0.0720.0363.470
Rpim0.0410.0211.981
Number of reflections389163187
<I/σ(I)>5.4
Completeness [%]92.196.456.4
Redundancy2.92.62.5
CC(1/2)0.9970.9970.153
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP8.62922 microliter 1.5 mM DNA solution (5mM HEPES pH 6.6) plus 2 microliter 10 mM HEPES pH 6.6 plus 4 microliter reservoir solution, against a reservoir of 1 ml 34% PEG200, 600 mM CaCl2 and 10 mM HEPES pH 8.6.