Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6QRW

X-ray radiation dose series on xylose isomerase - 3.25 MGy

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRL BEAMLINE BL11-1
Synchrotron siteSSRL
BeamlineBL11-1
Temperature [K]100
Detector technologyCCD
Collection date2004-05-01
DetectorADSC QUANTUM 315
Wavelength(s)0.954, 0.855
Spacegroup nameI 2 2 2
Unit cell lengths92.592, 97.609, 102.583
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution39.793 - 1.170
R-factor0.1064
Rwork0.105
R-free0.12360
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)6qrr
RMSD bond length0.010
RMSD bond angle1.174
Data reduction softwareXDS
Data scaling softwareAimless
Refinement softwarePHENIX ((1.14_3247: ???))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]39.8001.190
High resolution limit [Å]1.1701.170
Rmeas0.0900.734
Number of reflections154610
<I/σ(I)>10.2
Completeness [%]99.4
Redundancy3.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP295.152-propanol, ethylene glycol, HEPES, magnesium chloride

226707

PDB entries from 2024-10-30

PDB statisticsPDBj update infoContact PDBjnumon