6QRV
X-ray radiation dose series on xylose isomerase - 2.63 MGy
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRL BEAMLINE BL11-1 |
Synchrotron site | SSRL |
Beamline | BL11-1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2004-05-01 |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 0.954, 0.855 |
Spacegroup name | I 2 2 2 |
Unit cell lengths | 92.567, 97.577, 102.560 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 38.723 - 1.170 |
R-factor | 0.1049 |
Rwork | 0.104 |
R-free | 0.12390 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 6qrr |
RMSD bond length | 0.009 |
RMSD bond angle | 1.150 |
Data reduction software | XDS |
Data scaling software | Aimless |
Refinement software | PHENIX ((1.14_3247: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 38.700 | 1.190 |
High resolution limit [Å] | 1.170 | 1.170 |
Rmeas | 0.090 | 0.623 |
Number of reflections | 154466 | |
<I/σ(I)> | 10.5 | |
Completeness [%] | 99.4 | |
Redundancy | 3.5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 295.15 | 2-propanol, ethylene glycol, HEPES, magnesium chloride |