Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6QRR

X-ray radiation dose series on xylose isomerase - 0.13 MGy

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRL BEAMLINE BL11-1
Synchrotron siteSSRL
BeamlineBL11-1
Temperature [K]100
Detector technologyCCD
Collection date2004-05-01
DetectorADSC QUANTUM 315
Wavelength(s)0.954, 0.855
Spacegroup nameI 2 2 2
Unit cell lengths92.478, 97.459, 102.485
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution38.690 - 1.096
Rwork0.121
R-free0.14700
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1muw
Data reduction softwareXDS
Data scaling softwareAimless
Refinement softwareREFMAC (5)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]38.7001.135
High resolution limit [Å]1.0961.096
Rmerge0.070
Rmeas0.0720.438
Number of reflections180192
<I/σ(I)>10.7
Completeness [%]95.7
Redundancy3.3
CC(1/2)0.990
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP295.152-propanol, ethylene glycol, HEPES, magnesium chloride

226707

PDB entries from 2024-10-30

PDB statisticsPDBj update infoContact PDBjnumon