6QRR
X-ray radiation dose series on xylose isomerase - 0.13 MGy
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRL BEAMLINE BL11-1 |
Synchrotron site | SSRL |
Beamline | BL11-1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2004-05-01 |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 0.954, 0.855 |
Spacegroup name | I 2 2 2 |
Unit cell lengths | 92.478, 97.459, 102.485 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 38.690 - 1.096 |
Rwork | 0.121 |
R-free | 0.14700 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1muw |
Data reduction software | XDS |
Data scaling software | Aimless |
Refinement software | REFMAC (5) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 38.700 | 1.135 |
High resolution limit [Å] | 1.096 | 1.096 |
Rmerge | 0.070 | |
Rmeas | 0.072 | 0.438 |
Number of reflections | 180192 | |
<I/σ(I)> | 10.7 | |
Completeness [%] | 95.7 | |
Redundancy | 3.3 | |
CC(1/2) | 0.990 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 295.15 | 2-propanol, ethylene glycol, HEPES, magnesium chloride |