6QNW
Influenza A Polymerase Heterotrimer Human H3N2 Northern Territory 1968
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I24 |
Synchrotron site | Diamond |
Beamline | I24 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2017-09-22 |
Detector | DECTRIS PILATUS3 6M |
Wavelength(s) | 0.968620 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 336.480, 191.895, 235.735 |
Unit cell angles | 90.00, 91.50, 90.00 |
Refinement procedure
Resolution | 138.620 - 3.310 |
R-factor | 0.2377 |
Rwork | 0.235 |
R-free | 0.27870 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 5d9a |
RMSD bond length | 0.002 |
RMSD bond angle | 0.618 |
Data scaling software | autoPROC |
Phasing software | PHASER |
Refinement software | PHENIX (1.14_3260) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 235.654 | 3.916 |
High resolution limit [Å] | 3.310 | 3.321 |
Rmerge | 0.459 | 2.243 |
Rmeas | 0.476 | 2.363 |
Rpim | 0.126 | 0.626 |
Number of reflections | 123159 | 9466 |
<I/σ(I)> | 4.8 | 2 |
Completeness [%] | 95.3 | 80.7 |
Redundancy | 14.4 | 13.7 |
CC(1/2) | 0.988 | 0.646 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 6.4 | 293 | 1-1.6 M K/Na phosphate |