6QNM
Apo state of chemotaxis sensor ODP from T. denticola
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 24-ID-C |
| Synchrotron site | APS |
| Beamline | 24-ID-C |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2017-06-06 |
| Detector | DECTRIS PILATUS 6M-F |
| Wavelength(s) | 0.979200 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 45.219, 94.800, 117.093 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 49.810 - 2.100 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHASER |
| Refinement software | PHENIX |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 49.810 | 2.175 |
| High resolution limit [Å] | 2.100 | 2.100 |
| Number of reflections | 30165 | |
| <I/σ(I)> | 4.6 | |
| Completeness [%] | 99.9 | 99.8 |
| Redundancy | 6.6 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 294 | 0.1 M Imidazole pH 7.0, 20% PEG 4000 |