Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6QIZ

CI-2, conformation 2

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsALBA BEAMLINE XALOC
Synchrotron siteALBA
BeamlineXALOC
Temperature [K]100
Detector technologyPIXEL
Collection date2015-10-21
DetectorDECTRIS PILATUS3 6M
Wavelength(s)0.9792
Spacegroup nameP 6 2 2
Unit cell lengths68.550, 68.550, 53.099
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution39.580 - 1.650
R-factor0.186
Rwork0.184
R-free0.22000
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2ci2
RMSD bond length0.006
RMSD bond angle0.862
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHENIX
Refinement softwarePHENIX ((1.10_2155: ???))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]39.5801.710
High resolution limit [Å]1.6501.650
Rmerge0.083
Number of reflections9305
<I/σ(I)>15.21.6
Completeness [%]100.0100
Redundancy8.38.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP8.529325% PEG 3350, 100 MM TRIS-HCL PH 8.5 AND 200 MM LITHIUM SULPHATE, VAPOR DIFFUSION, SITTING DROP, TEMPERATURE 293K

219140

PDB entries from 2024-05-01

PDB statisticsPDBj update infoContact PDBjnumon