6Q25

Coiled-coil Trimer with Glu:Leu:Lys Triad

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsENRAF-NONIUS FR591
Temperature [K]100
Detector technologyCCD
Collection date2017-09-29
DetectorAPEX II CCD
Wavelength(s)1.5406
Spacegroup nameH 3
Unit cell lengths39.063, 39.063, 101.522
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution17.409 - 1.893
R-factor0.1818
Rwork0.176
R-free0.22790
Structure solution methodMOLECULAR REPLACEMENT
Data reduction softwarePROTEUM PLUS
Data scaling softwarePROTEUM PLUS
Phasing softwarePHENIX
Refinement softwarePHENIX (dev_2906)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]17.4091.961
High resolution limit [Å]1.8931.893
Rmerge0.1910.532
Rmeas0.2110.658
Rpim0.0870.380
Number of reflections4584469
<I/σ(I)>9.91.4
Completeness [%]98.9
Redundancy4.9
CC(1/2)0.9480.668
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP7.529850% PEG200, 100 mM HEPES free acid/NaOH, pH 7.5

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon