Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX2 |
Synchrotron site | Australian Synchrotron |
Beamline | MX2 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2018-02-07 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 0.95373 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 87.620, 89.960, 130.529 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 45.240 - 2.000 |
R-factor | 0.1877 |
Rwork | 0.186 |
R-free | 0.22290 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3u5t |
RMSD bond length | 0.007 |
RMSD bond angle | 0.781 |
Data reduction software | iMOSFLM |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | PHENIX (1.14_3260) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 45.240 | 2.040 |
High resolution limit [Å] | 2.000 | 2.000 |
Rmerge | 0.099 | 0.346 |
Rmeas | 0.116 | 0.405 |
Rpim | 0.060 | 0.207 |
Number of reflections | 70331 | 4491 |
<I/σ(I)> | 7.5 | 3.6 |
Completeness [%] | 99.9 | |
Redundancy | 3.6 | |
CC(1/2) | 0.843 | 0.772 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 296.15 | 0.1 M HEPES, pH 7.5, 0.8 M potassium sodium tartrate |