Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6PIL

Antibody scFv-M204 monomeric state

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 24-ID-C
Synchrotron siteAPS
Beamline24-ID-C
Temperature [K]100
Detector technologyPIXEL
Collection date2018-08-17
DetectorDECTRIS PILATUS 6M-F
Wavelength(s)0.7749
Spacegroup nameP 41 2 2
Unit cell lengths60.420, 60.420, 159.420
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution56.500 - 2.200
R-factor0.198
Rwork0.194
R-free0.23400
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.010
RMSD bond angle1.150
Data reduction softwareXDS
Data scaling softwareXSCALE (20180126)
Phasing softwarePHASER
Refinement softwareBUSTER (2.10.3)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]56.50056.5002.260
High resolution limit [Å]2.2009.8402.200
Rmerge0.0720.0220.644
Rmeas0.0840.0270.752
Total number of observations55416
Number of reflections154222201120
<I/σ(I)>11.1432.341.91
Completeness [%]97.994.499
Redundancy3.5933.1093.653
CC(1/2)0.9991.0000.736
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP4.22980.2 M Lithium sulfate, 0.1 M Phosphate/Citrate pH 4.2, 20% PEG 1000