6PFT

rsEGFP2 with a chlorinated chromophore in the non-fluorescent off-state

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRL BEAMLINE BL14-1
Synchrotron siteSSRL
BeamlineBL14-1
Temperature [K]100
Detector technologyCCD
Collection date2018-07-21
DetectorMARMOSAIC 325 mm CCD
Wavelength(s)1.305053
Spacegroup nameP 21 21 21
Unit cell lengths51.014, 62.716, 68.619
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution34.309 - 1.450
R-factor0.1513
Rwork0.150
R-free0.17580
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)5dty
RMSD bond length0.020
RMSD bond angle1.649
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHENIX
Refinement softwarePHENIX (1.13_2998)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]34.3091.502
High resolution limit [Å]1.4501.450
Rmerge0.0080.089
Rmeas0.0120.127
Number of reflections389923674
<I/σ(I)>21.465.52
Completeness [%]98.293.61
Redundancy22
CC(1/2)1.0000.982
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP8.12981.76 M ammonium sulfate, 0.1 M HEPES; Cryoprotectant 1 M sucrose, 1.7 M ammonium sulfate, 0.1 M HEPES.