6P9P
E.coli LpxA in complex with Compound 1
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU FR-E SUPERBRIGHT |
| Temperature [K] | 100 |
| Detector technology | IMAGE PLATE |
| Collection date | 2015-01-14 |
| Detector | RIGAKU RAXIS IV |
| Wavelength(s) | 1.5418 |
| Spacegroup name | P 21 3 |
| Unit cell lengths | 96.228, 96.228, 96.228 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 43.034 - 2.000 |
| R-factor | 0.1882 |
| Rwork | 0.186 |
| R-free | 0.22320 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 1lxa |
| Data reduction software | XDS |
| Data scaling software | SCALA (0.7.2) |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.14_3211) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 48.110 | 48.110 | 2.050 |
| High resolution limit [Å] | 2.000 | 8.950 | 2.000 |
| Rmerge | 0.121 | 0.021 | 1.243 |
| Rmeas | 0.143 | 0.026 | 1.480 |
| Rpim | 0.074 | 0.015 | 0.793 |
| Total number of observations | 72097 | 691 | 4962 |
| Number of reflections | 20275 | 247 | 1471 |
| <I/σ(I)> | 8.5 | 30.8 | 1 |
| Completeness [%] | 99.6 | 94 | 99.6 |
| Redundancy | 3.6 | 2.8 | 3.4 |
| CC(1/2) | 0.996 | 0.999 | 0.372 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 7 | 298 | 0.1M Na/K phosphate, 10% PEG 1000 |