6OVV
Coiled-coil Trimer with Glu:4-pyridinylalanine:Lys Triad
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | ENRAF-NONIUS FR591 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2017-10-04 |
Detector | APEX II CCD |
Wavelength(s) | 1.5406 |
Spacegroup name | H 3 |
Unit cell lengths | 38.379, 38.379, 119.428 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 17.290 - 2.201 |
R-factor | 0.194 |
Rwork | 0.186 |
R-free | 0.26390 |
Structure solution method | MOLECULAR REPLACEMENT |
Data reduction software | PROTEUM PLUS |
Data scaling software | PROTEUM PLUS |
Phasing software | PHENIX |
Refinement software | PHENIX (dev_2906) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 17.290 | 2.280 |
High resolution limit [Å] | 2.200 | 2.201 |
Rpim | 0.083 | 0.342 |
Number of reflections | 3330 | 342 |
<I/σ(I)> | 7.5 | |
Completeness [%] | 100.0 | |
Redundancy | 4.9 | |
CC(1/2) | 0.993 | 0.742 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 298 | 40% PEG300, 100 mM sodium phosphate dibasic/citric acid, pH 4.2 |