6OSN
Potent and Selective Antitumor Antibody Targeting a Membrane-Proximal Epitope of ROR2
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 21-ID-F |
Synchrotron site | APS |
Beamline | 21-ID-F |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2015-11-20 |
Detector | MARMOSAIC 225 mm CCD |
Wavelength(s) | 0.97872 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 33.606, 41.917, 52.150 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 22.141 - 1.083 |
R-factor | 0.1533 |
Rwork | 0.153 |
R-free | 0.16090 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 6ba5 |
RMSD bond length | 0.008 |
RMSD bond angle | 0.948 |
Data reduction software | XDS |
Data scaling software | SCALA |
Phasing software | PHASER |
Refinement software | PHENIX ((1.15.2_3472: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 32.671 | 1.122 |
High resolution limit [Å] | 1.021 | 1.083 |
Rmerge | 0.021 | 0.059 |
Rmeas | 0.025 | 0.079 |
Rpim | 0.013 | 0.051 |
Number of reflections | 29243 | 29243 |
<I/σ(I)> | 35.5 | |
Completeness [%] | 76.7 | |
Redundancy | 3.1 | |
CC(1/2) | 0.999 | 0.993 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 294 | 0.2 M Li acetate 20% PEG 3350 |