6OGK

MeCP2 MBD in complex with DNA

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsALS BEAMLINE 5.0.1
Synchrotron siteALS
Beamline5.0.1
Temperature [K]100
Detector technologyPIXEL
Collection date2018-09-22
DetectorDECTRIS PILATUS3 6M
Wavelength(s)0.97741
Spacegroup nameP 21 21 21
Unit cell lengths40.470, 51.976, 66.304
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution40.900 - 1.650
R-factor0.2289
Rwork0.226
R-free0.25520
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)6c1y
RMSD bond length0.011
RMSD bond angle1.743
Data reduction softwareXDS
Data scaling softwareAimless (0.7.2)
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0238)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]40.91040.9101.630
High resolution limit [Å]1.6008.7801.600
Rmerge0.0600.0141.835
Rmeas0.0650.0162.092
Rpim0.0260.0070.982
Total number of observations1157837263650
Number of reflections18969
<I/σ(I)>17.582.50.7
Completeness [%]99.899.597.3
Redundancy6.14.84.1
CC(1/2)1.0001.0000.366
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION6.529150% precipitant mix 4, 0.1M buffer system 1, 0.06M divalents (morpheus A4)