6N5J
FtsY-NG high-resolution
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX2 |
Synchrotron site | Australian Synchrotron |
Beamline | MX2 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2017-09-19 |
Detector | ADSC QUANTUM 210r |
Wavelength(s) | 0.9536 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 34.784, 76.104, 108.704 |
Unit cell angles | 90.00, 93.95, 90.00 |
Refinement procedure
Resolution | 44.160 - 1.370 |
R-factor | 0.1411 |
Rwork | 0.139 |
R-free | 0.17910 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.008 |
RMSD bond angle | 0.895 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | PHENIX ((1.11.1_2575: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 44.160 | 1.419 |
High resolution limit [Å] | 1.370 | 1.370 |
Rmerge | 0.018 | 0.172 |
Rpim | 0.018 | 0.172 |
Number of reflections | 118474 | |
<I/σ(I)> | 16.9 | 4.14 |
Completeness [%] | 99.9 | 99.7 |
Redundancy | 2 | 2 |
CC(1/2) | 0.999 | 0.921 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 297.15 | 0.1 M Bis-Tris pH 5.8, 215 mM ammonium acetate, %20 PEG 3350 |