6N5I
FtsY-NG high-resolution
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX1 |
Synchrotron site | Australian Synchrotron |
Beamline | MX1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2017-05-19 |
Detector | ADSC QUANTUM 210r |
Wavelength(s) | 0.9537 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 34.753, 76.207, 108.989 |
Unit cell angles | 90.00, 93.85, 90.00 |
Refinement procedure
Resolution | 34.670 - 1.498 |
R-factor | 0.1352 |
Rwork | 0.133 |
R-free | 0.18180 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.003 |
RMSD bond angle | 0.635 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | PHENIX ((1.11.1_2575: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 34.670 | 1.552 |
High resolution limit [Å] | 1.498 | 1.498 |
Rmerge | 0.023 | 0.132 |
Rmeas | 0.032 | 0.186 |
Rpim | 0.023 | 0.132 |
Number of reflections | 88464 | |
<I/σ(I)> | 18.22 | |
Completeness [%] | 97.3 | 96.78 |
Redundancy | 1.8 | 1.7 |
CC(1/2) | 0.999 | 0.957 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 5.8 | 297.15 | 0.1 M Bis-Tris pH 5.8, 26.5% PEG 2000 MME, 175 mM KBr |