Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6N4Z

Tetragonal thermolysin (with 50% xylose) plunge cooled in liquid nitrogen to 77 K

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSEALED TUBE
Source detailsOXFORD DIFFRACTION NOVA
Temperature [K]100
Detector technologyCCD
Collection date2018-10-21
DetectorOXFORD ONYX CCD
Wavelength(s)1.54
Spacegroup nameP 41 21 2
Unit cell lengths96.725, 96.725, 106.535
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution29.400 - 1.400
R-factor0.14
Rwork0.139
R-free0.16120
Structure solution methodSAD
RMSD bond length0.007
RMSD bond angle0.903
Data reduction softwareCrysalisPro (1.14_3260)
Data scaling softwareCrysalisPro
Phasing softwarePHENIX
Refinement softwarePHENIX (1.14_3260)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]29.4001.450
High resolution limit [Å]1.4001.400
Rmerge0.0812.820
Rmeas3.000
Rpim0.0241.030
Number of reflections987719449
<I/σ(I)>20.30.72
Completeness [%]99.296.1
Redundancy11.68.2
CC(1/2)0.9990.277
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP295Drop: 75 mg/ml protein in 45% DMSO/0.5 ZnCl2, Well: 1 M Ammonium sulfate

225946

PDB entries from 2024-10-09

PDB statisticsPDBj update infoContact PDBjnumon