6MB5

AAC-IIIb binary with NEOMYCIN

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 23-ID-D
Synchrotron siteAPS
Beamline23-ID-D
Temperature [K]100
Detector technologyPIXEL
Collection date2018-08-01
DetectorDECTRIS PILATUS3 6M
Wavelength(s)1
Spacegroup nameP 32 2 1
Unit cell lengths106.120, 106.120, 68.970
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution45.951 - 2.200
R-factor0.2454
Rwork0.245
R-free0.26080
Data reduction softwareMOSFLM
Data scaling softwareAimless (0.6.3)
Phasing softwarePHASER
Refinement softwarePHENIX (1.13_2998)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]45.95145.9502.270
High resolution limit [Å]2.2009.0702.200
Rmerge0.0910.0480.534
Rmeas0.1070.0570.634
Rpim0.0550.0290.334
Number of reflections227203681933
<I/σ(I)>7.5
Completeness [%]98.798.997.8
Redundancy3.53.53.3
CC(1/2)0.9950.9950.880
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.62831-3%PEG 4000, 20-25% isopropanol,0.1M HEPES, pH=7.5