6M8W
PSEUDOMONAS SERINE-CARBOXYL PROTEINASE (SEDOLISIN) COMPLEXED WITH THE INHIBITOR AIAF
Replaces: 1KDVExperimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | NSLS BEAMLINE X9B |
Synchrotron site | NSLS |
Beamline | X9B |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2001-05-21 |
Detector | ADSC QUANTUM 4 |
Wavelength(s) | 0.92 |
Spacegroup name | P 62 |
Unit cell lengths | 97.290, 97.290, 83.460 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 30.000 - 1.100 |
R-factor | 0.1313 |
R-free | 0.14960 |
RMSD bond length | 0.015 |
RMSD bond angle | 0.028 |
Data reduction software | HKL-2000 |
Data scaling software | SCALEPACK |
Refinement software | SHELXL (2018/3) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 40.000 | 1.140 |
High resolution limit [Å] | 1.100 | 1.100 |
Rmerge | 0.059 | 0.519 |
Number of reflections | 181240 | 18046 |
<I/σ(I)> | 13.7 | |
Completeness [%] | 100.0 | 100 |
Redundancy | 5.8 | 3.8 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 4.3 | 298 | Ammonium sulfate, CaCl2, Glycerol, Guanidine hydrochloride |