Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6M7M

rac-GSTSTA from degenerate octameric repeats in InaZ, residues 707-712

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 24-ID-E
Synchrotron siteAPS
Beamline24-ID-E
Temperature [K]100
Detector technologyPIXEL
Collection date2017-10-25
DetectorDECTRIS EIGER X 16M
Wavelength(s)0.9791
Spacegroup nameP 1 21/c 1
Unit cell lengths15.230, 9.290, 21.060
Unit cell angles90.00, 108.23, 90.00
Refinement procedure
Resolution14.466 - 1.101
R-factor0.2023
Rwork0.199
R-free0.23630
RMSD bond length0.007
RMSD bond angle0.769
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwareSHELXD
Refinement softwarePHENIX (1.12_2829)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]14.46614.4661.130
High resolution limit [Å]1.1004.9201.100
Rmerge0.0760.0420.193
Rmeas0.0940.0570.247
Number of reflections209723130
<I/σ(I)>6.9913.32.75
Completeness [%]94.49284.4
Redundancy2.8522.8262.392
CC(1/2)0.9960.9980.994
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP82980.1M imidazole pH 8.0, 10% (w/v) of PEG 8000

226707

PDB entries from 2024-10-30