Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6LF0

Structure of FEM1C

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRF BEAMLINE BL17U1
Synchrotron siteSSRF
BeamlineBL17U1
Temperature [K]100
Detector technologyCCD
Collection date2019-01-12
DetectorADSC QUANTUM 315
Wavelength(s)0.979
Spacegroup nameP 21 21 21
Unit cell lengths88.720, 98.480, 146.570
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution56.502 - 2.110
R-factor0.1966
Rwork0.195
R-free0.22910
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)6lbf
Data reduction softwareHKL-3000
Data scaling softwareHKL-3000
Phasing softwarePHASER
Refinement softwarePHENIX (1.14_3260)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]81.7402.160
High resolution limit [Å]2.1102.110
Number of reflections744457352
<I/σ(I)>19.7
Completeness [%]99.9
Redundancy13.4
CC(1/2)0.9990.820
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2910.2M Lithium sulfate, 0.1M Tris-HCl pH 7.3

222926

PDB entries from 2024-07-24

PDB statisticsPDBj update infoContact PDBjnumon