6KJY
Galectin-13 variant C136S/C138S
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRF BEAMLINE BL18U1 |
| Synchrotron site | SSRF |
| Beamline | BL18U1 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2019-04-21 |
| Detector | DECTRIS PILATUS 6M |
| Wavelength(s) | 0.97 |
| Spacegroup name | P 43 21 2 |
| Unit cell lengths | 53.510, 53.510, 113.766 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 19.499 - 1.500 |
| R-factor | 0.1869 |
| Rwork | 0.185 |
| R-free | 0.20500 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.009 |
| RMSD bond angle | 1.006 |
| Refinement software | PHENIX (1.12_2829) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 19.500 | 1.530 |
| High resolution limit [Å] | 1.500 | 1.500 |
| Number of reflections | 27251 | 1260 |
| <I/σ(I)> | 35.7 | |
| Completeness [%] | 99.6 | |
| Redundancy | 11.6 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 298 | Bis-Tris |