6KGJ
M1Q-hNTAQ1 C28S
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | PAL/PLS BEAMLINE 5C (4A) |
Synchrotron site | PAL/PLS |
Beamline | 5C (4A) |
Temperature [K] | 193 |
Detector technology | PIXEL |
Collection date | 2018-12-10 |
Detector | DECTRIS EIGER X 9M |
Wavelength(s) | 0.97957 |
Spacegroup name | I 2 2 2 |
Unit cell lengths | 95.638, 105.779, 140.169 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 35.470 - 1.800 |
R-factor | 0.2115 |
Rwork | 0.211 |
R-free | 0.22300 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4w79 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHENIX |
Refinement software | PHENIX (1.13_2998) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 1.840 |
High resolution limit [Å] | 1.800 | 1.800 |
Number of reflections | 65207 | 6176 |
<I/σ(I)> | 25.9 | |
Completeness [%] | 100.0 | |
Redundancy | 6.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 293 | 0.4M ammonium sulfate, 0.1M sodium citrate tribasic dihydrate pH 5.6, 1.0M lithium sulfate monohydrate |