6JV7
Chimeric Rat C5a
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU MICROMAX-007 HF |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2017-12-23 |
Detector | DECTRIS PILATUS 200K |
Wavelength(s) | 1.54 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 27.709, 57.609, 81.760 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 33.339 - 1.309 |
R-factor | 0.1987 |
Rwork | 0.196 |
R-free | 0.25090 |
RMSD bond length | 0.006 |
RMSD bond angle | 0.950 |
Data reduction software | HKL-3000 |
Data scaling software | HKL-3000 |
Phasing software | PHENIX |
Refinement software | PHENIX ((1.13_2998: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 1.350 |
High resolution limit [Å] | 1.300 | 1.300 |
Number of reflections | 33053 | |
<I/σ(I)> | 17.31 | |
Completeness [%] | 66.3 | |
Redundancy | 3.4 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 291.15 | 0.1M HEPES sodium, pH 7.5, 2.0M ammonium sulfate, 2% v/v polyethylene glycol 400 |