6J4M
Thermal treated soybean seed H-2 ferritin
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL17U1 |
Synchrotron site | SSRF |
Beamline | BL17U1 |
Temperature [K] | 80 |
Detector technology | CCD |
Collection date | 2018-04-03 |
Detector | MARMOSAIC 225 mm CCD |
Wavelength(s) | 0.9789 |
Spacegroup name | I 2 3 |
Unit cell lengths | 149.902, 149.902, 149.902 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 40.060 - 2.598 |
R-factor | 0.195 |
Rwork | 0.194 |
R-free | 0.22380 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3a68 |
RMSD bond length | 0.008 |
RMSD bond angle | 0.950 |
Data reduction software | HKL-3000 |
Data scaling software | HKL-3000 |
Phasing software | HKL-3000 |
Refinement software | PHENIX ((1.10.1_2155: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 40.060 | 2.691 |
High resolution limit [Å] | 2.598 | 2.598 |
Number of reflections | 17380 | |
<I/σ(I)> | 4.5 | |
Completeness [%] | 100.0 | |
Redundancy | 11.5 | |
CC(1/2) | 0.990 | 0.990 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | EVAPORATION | 293 | Magnesium chloride, Tris, 1,6-hexylene glycol |