6IVC
The full length of TGEV nsp1
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL17U1 |
Synchrotron site | SSRF |
Beamline | BL17U1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2017-07-10 |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 1.0 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 36.164, 67.008, 90.101 |
Unit cell angles | 90.00, 93.98, 90.00 |
Refinement procedure
Resolution | 34.315 - 1.800 |
R-factor | 0.1836 |
Rwork | 0.181 |
R-free | 0.23210 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3zbd |
Data reduction software | HKL-3000 |
Data scaling software | HKL-3000 |
Phasing software | PHENIX |
Refinement software | PHENIX (1.14_3260) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 34.315 | 1.845 |
High resolution limit [Å] | 1.800 | 1.800 |
Rmerge | 0.056 | 0.476 |
Number of reflections | 38588 | 38588 |
<I/σ(I)> | 20.16 | |
Completeness [%] | 96.9 | |
Redundancy | 4.18 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 293 | PEG3350, Lithium chloride |