6IR7
Green fluorescent protein variant GFPuv with the modification to 6-hydroxynorleucine at the C-terminus
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SPRING-8 BEAMLINE BL41XU |
Synchrotron site | SPring-8 |
Beamline | BL41XU |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2014-07-18 |
Detector | DECTRIS PILATUS3 6M |
Wavelength(s) | 1.0 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 47.295, 51.152, 48.506 |
Unit cell angles | 90.00, 100.79, 90.00 |
Refinement procedure
Resolution | 47.649 - 1.277 |
R-factor | 0.1758 |
Rwork | 0.175 |
R-free | 0.19510 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1b9c |
RMSD bond length | 0.006 |
RMSD bond angle | 1.140 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | MOLREP |
Refinement software | PHENIX (1.9_1692) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 1.300 |
High resolution limit [Å] | 1.280 | 1.280 |
Number of reflections | 56911 | 2566 |
<I/σ(I)> | 27.8 | 7.2 |
Completeness [%] | 96.3 | 87.4 |
Redundancy | 3.1 | 2.9 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 293 | 0.2 M Ammonium Sulfate, 0.1 M MES pH 6.5, 30% PEGMME5000 |