6ILU
Endolysin LysPBC5 CBD
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | PAL/PLS BEAMLINE 5C (4A) |
Synchrotron site | PAL/PLS |
Beamline | 5C (4A) |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2018-01-05 |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 0.9796 |
Spacegroup name | I 2 2 2 |
Unit cell lengths | 81.823, 107.514, 117.524 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 36.361 - 1.601 |
R-factor | 0.168 |
Rwork | 0.167 |
R-free | 0.19630 |
Structure solution method | SAD |
RMSD bond length | 0.015 |
RMSD bond angle | 1.454 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | SOLVE |
Refinement software | PHENIX (1.9_1692) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 1.641 |
High resolution limit [Å] | 1.601 | 1.601 |
Rmerge | 0.061 | 0.337 |
Number of reflections | 65554 | 5078 |
<I/σ(I)> | 54.58 | |
Completeness [%] | 96.0 | |
Redundancy | 9.8 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |