6IFT
KsgA from Bacillus subtilis in complex with SAM
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE BM14 |
Synchrotron site | ESRF |
Beamline | BM14 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2016-12-25 |
Detector | MARMOSAIC 225 mm CCD |
Wavelength(s) | 0.98 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 45.200, 81.970, 47.120 |
Unit cell angles | 90.00, 112.02, 90.00 |
Refinement procedure
Resolution | 19.280 - 1.900 |
R-factor | 0.17913 |
Rwork | 0.177 |
R-free | 0.23495 |
RMSD bond length | 0.019 |
RMSD bond angle | 2.043 |
Data reduction software | MOSFLM |
Data scaling software | SCALA |
Phasing software | Auto-Rickshaw |
Refinement software | REFMAC (5.8.0189) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 19.280 | 1.949 |
High resolution limit [Å] | 1.900 | 1.900 |
Number of reflections | 25102 | |
<I/σ(I)> | 12 | 3.5 |
Completeness [%] | 99.9 | 100 |
Redundancy | 3.3 | 3.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 8% tacsimate pH 6.0, 20% PEG 3350 |