6I74
Galectin-3C in complex with substituted polyfluoroaryl monothiogalactoside derivative 1
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | MAX II BEAMLINE I911-3 |
Synchrotron site | MAX II |
Beamline | I911-3 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2015-05-03 |
Detector | MARMOSAIC 225 mm CCD |
Wavelength(s) | 1.0 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 36.654, 57.781, 62.755 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 27.574 - 0.959 |
R-factor | 0.1326 |
Rwork | 0.132 |
R-free | 0.14730 |
Structure solution method | FOURIER SYNTHESIS |
Starting model (for MR) | 3zsl |
RMSD bond length | 0.011 |
RMSD bond angle | 1.227 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHENIX |
Refinement software | PHENIX ((dev_3084: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 26.240 | 0.994 |
High resolution limit [Å] | 0.959 | 0.959 |
Rmerge | 0.043 | 1.207 |
Rpim | 0.019 | 0.708 |
Number of reflections | 77623 | |
<I/σ(I)> | 24.15 | 0.93 |
Completeness [%] | 94.4 | 78.51 |
Redundancy | 5.8 | 3.5 |
CC(1/2) | 1.000 | 0.409 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 298 | 30% PEG 4000, 0.1 M Tris/HCl pH 7.5, 0.1 M MgCl2, 0.4 M NaSCN, 7.9 mM beta-mercaptoethanol |