6HYV

THE GLIC PENTAMERIC LIGAND-GATED ION CHANNEL MUTANT Y119A

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSOLEIL BEAMLINE PROXIMA 2
Synchrotron siteSOLEIL
BeamlinePROXIMA 2
Temperature [K]193
Detector technologyPIXEL
Collection date2016-12-18
DetectorDECTRIS EIGER X 9M
Wavelength(s)0.9785
Spacegroup nameC 1 2 1
Unit cell lengths180.810, 132.380, 159.650
Unit cell angles90.00, 102.22, 90.00
Refinement procedure
Resolution20.000 - 2.800
R-factor0.2093
Rwork0.209
R-free0.22120
RMSD bond length0.010
RMSD bond angle1.130
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHASER
Refinement softwareBUSTER (2.10.2)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]49.2302.850
High resolution limit [Å]2.8002.800
Number of reflections90262
<I/σ(I)>9.7
Completeness [%]99.8
Redundancy3.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1EVAPORATION29112-14.5% PEG4K; 15% GLycerol; 400 mM NaSCN; 3% DMSO; 100mM NaAcetate pH 4

218853