6HXB

SERCA2a from pig heart

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X06SA
Synchrotron siteSLS
BeamlineX06SA
Temperature [K]77
Detector technologyPIXEL
Collection date2014-09-19
DetectorDECTRIS PILATUS 6M
Wavelength(s)1
Spacegroup nameP 1 2 1
Unit cell lengths116.995, 51.776, 125.604
Unit cell angles90.00, 106.13, 90.00
Refinement procedure
Resolution41.724 - 4.000
Rwork0.310
R-free0.35440
RMSD bond length0.010
RMSD bond angle0.533
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHENIX
Refinement softwarePHENIX ((1.11.1_2575: ???))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]42.7004.500
High resolution limit [Å]4.0004.000
Number of reflections12416
<I/σ(I)>4.2
Completeness [%]98.7
Redundancy3.7
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP292.1521% PEG2000 monomethyl ether, 20% glycerol, 100 mM NaCl, 5% tert-BuOH and 2.4% Zwittergent-3-08