Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6HAO

MamM CTD H264E - Cadmium form 2

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsBESSY BEAMLINE 14.1
Synchrotron siteBESSY
Beamline14.1
Temperature [K]100
Detector technologyPIXEL
Collection date2017-08-19
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.9184
Spacegroup nameP 31 2 1
Unit cell lengths53.661, 53.661, 58.074
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution46.470 - 2.400
R-factor0.24499
Rwork0.238
R-free0.31440
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3w5x
RMSD bond length0.005
RMSD bond angle0.900
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0216)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]46.4702.490
High resolution limit [Å]2.4002.400
Rmerge0.169
Number of reflections3988
<I/σ(I)>11.92.3
Completeness [%]98.688.4
Redundancy9.24.7
CC(1/2)0.9940.910
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2930.2M MgCl2, 0.1M BIS-TRIS pH=6.5, 25% PEG 3350, 1.7mM CdCl2

222624

PDB entries from 2024-07-17

PDB statisticsPDBj update infoContact PDBjnumon