Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6H8A

MamM CTD D249N - Cadmium form

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID29
Synchrotron siteESRF
BeamlineID29
Temperature [K]100
Detector technologyPIXEL
Collection date2018-02-01
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.975
Spacegroup nameC 2 2 21
Unit cell lengths36.844, 94.661, 53.438
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution47.330 - 1.800
R-factor0.1968
Rwork0.192
R-free0.23669
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3w5x
RMSD bond length0.013
RMSD bond angle1.592
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0216)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]47.3301.840
High resolution limit [Å]1.8001.800
Rmerge0.145
Number of reflections9025533
<I/σ(I)>12.31.8
Completeness [%]100.0100
Redundancy12.212.8
CC(1/2)0.9970.666
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2930.2M Li2SO4, 0.1M BIS-TRIS pH=5.5, 25% PEG 3350, 1.7mM CdCl2

226707

PDB entries from 2024-10-30

PDB statisticsPDBj update infoContact PDBjnumon