6H85
MamM CTD H264E-E289H - Cadmium form
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I04 |
Synchrotron site | Diamond |
Beamline | I04 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2017-07-27 |
Detector | DECTRIS PILATUS 6M-F |
Wavelength(s) | 0.9795 |
Spacegroup name | C 2 2 21 |
Unit cell lengths | 36.231, 94.249, 53.096 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 47.120 - 2.000 |
R-factor | 0.18932 |
Rwork | 0.186 |
R-free | 0.22012 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3w5x |
RMSD bond length | 0.013 |
RMSD bond angle | 1.606 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0171) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 53.100 | 2.050 |
High resolution limit [Å] | 2.000 | 2.000 |
Rmerge | 0.051 | |
Number of reflections | 6470 | |
<I/σ(I)> | 29.1 | 8.9 |
Completeness [%] | 99.6 | 95.1 |
Redundancy | 12.4 | 10.2 |
CC(1/2) | 0.999 | 0.993 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 293 | 0.2M AmSu, 0.1M BIS-TRIS pH=5.5, 25% PEG 3350, 1.7mM CdCl2 |