Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6H83

MamM CTD D249H - Copper form

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID23-1
Synchrotron siteESRF
BeamlineID23-1
Temperature [K]100
Detector technologyPIXEL
Collection date2017-06-29
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.977999
Spacegroup nameC 2 2 21
Unit cell lengths36.696, 95.071, 53.728
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution35.600 - 1.500
R-factor0.19563
Rwork0.194
R-free0.22284
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3w5x
RMSD bond length0.013
RMSD bond angle1.587
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0230)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]35.6001.520
High resolution limit [Å]1.5001.500
Rmerge0.058
Number of reflections15478
<I/σ(I)>20.11.4
Completeness [%]99.691.6
Redundancy13
CC(1/2)0.9990.723
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2930.2M AmSu, 0.1M BIS-TRIS pH=5.5, 25% PEG 3350, 1.7mM CuSO4

223790

PDB entries from 2024-08-14

PDB statisticsPDBj update infoContact PDBjnumon