Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SOLEIL BEAMLINE PROXIMA 1 |
Synchrotron site | SOLEIL |
Beamline | PROXIMA 1 |
Temperature [K] | 273.15 |
Detector technology | CCD |
Collection date | 2015-07-10 |
Detector | ADSC QUANTUM 315r |
Wavelength(s) | 0.97620 |
Spacegroup name | P 6 |
Unit cell lengths | 123.023, 123.023, 60.880 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 40.269 - 2.892 |
R-factor | 0.2065 |
Rwork | 0.205 |
R-free | 0.23730 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2c9o |
RMSD bond length | 0.002 |
RMSD bond angle | 0.424 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | PHENIX ((1.13_2992: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 52.859 | 2.940 |
High resolution limit [Å] | 2.892 | 2.892 |
Rmerge | 0.111 | |
Rmeas | 0.129 | |
Rpim | 0.063 | |
Number of reflections | 11583 | |
<I/σ(I)> | 11.3 | |
Completeness [%] | 97.0 | |
Redundancy | 3.9 | |
CC(1/2) | 0.996 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 6 | 303.15 | PEG 3350, Magnesium Chloride |