6GXT
The hit-and-return system enables efficient time-resolved serial synchrotron crystallography: FAcD2052MS after reaction initiation
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | PETRA III, EMBL c/o DESY BEAMLINE P14 (MX2) |
Synchrotron site | PETRA III, EMBL c/o DESY |
Beamline | P14 (MX2) |
Temperature [K] | 293 |
Detector technology | PIXEL |
Collection date | 2016-06-24 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.96269 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 41.760, 79.540, 84.460 |
Unit cell angles | 90.00, 102.94, 90.00 |
Refinement procedure
Resolution | 57.199 - 1.950 |
R-factor | 0.1836 |
Rwork | 0.181 |
R-free | 0.22770 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3r3u |
RMSD bond length | 0.008 |
RMSD bond angle | 0.905 |
Data reduction software | XDS (nXDS) |
Data scaling software | XSCALE (nXSCALE) |
Phasing software | PHASER |
Refinement software | PHENIX ((1.12_2829: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 57.510 | 2.000 |
High resolution limit [Å] | 1.950 | 1.950 |
Number of reflections | 39351 | |
<I/σ(I)> | 4 | |
Completeness [%] | 99.9 | |
Redundancy | 59.2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | BATCH MODE | 293 | PEG 3350 18 - 20 % CaCl 200 mM TrisHCL 100 mM pH 8.5 |