6GO3
TdT chimera (Loop1 of pol mu) - apoenzyme
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SOLEIL BEAMLINE PROXIMA 1 |
Synchrotron site | SOLEIL |
Beamline | PROXIMA 1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2017-03-09 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.9785 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 46.870, 85.280, 119.710 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 41.080 - 2.200 |
R-factor | 0.203 |
Rwork | 0.201 |
R-free | 0.25100 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1jms |
RMSD bond length | 0.010 |
RMSD bond angle | 1.050 |
Data reduction software | XDS |
Data scaling software | SCALA |
Phasing software | PHASER |
Refinement software | BUSTER (2.10.3) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 46.810 | 2.330 |
High resolution limit [Å] | 2.200 | 2.200 |
Rmerge | 0.135 | 1.612 |
Number of reflections | 25171 | 3964 |
<I/σ(I)> | 9.57 | |
Completeness [%] | 99.7 | 98.8 |
Redundancy | 7.1 | |
CC(1/2) | 0.997 | 0.512 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6 | 291 | 20-24% PEG 6000, 400-800 mM lithium chloride, 100 mM MES |