6G87

Flavonoid-responsive Regulator FrrA

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsBESSY BEAMLINE 14.1
Synchrotron siteBESSY
Beamline14.1
Temperature [K]100
Detector technologyPIXEL
Collection date2015-09-01
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.979031
Spacegroup nameP 43
Unit cell lengths119.592, 119.592, 78.476
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution47.560 - 2.920
R-factor0.18383
Rwork0.183
R-free0.21112
Structure solution methodMAD
RMSD bond length0.012
RMSD bond angle1.552
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwareAuto-Rickshaw
Refinement softwareREFMAC (5.8.0073)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]47.5703.100
High resolution limit [Å]2.9192.919
Rmeas0.1010.931
Number of reflections470287487
<I/σ(I)>15.171.96
Completeness [%]99.699
Redundancy7.027.17
CC(1/2)0.999
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP2916mg/ml FrrA in 20 mM Na2HPO4, 100 mM imidazole, pH 7.5, 50 mM NaCl. Precipitant 20 % PEG 8000; 0.1 M CHES, pH 9.5.