Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6FZY

PPAR mutant

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID23-1
Synchrotron siteESRF
BeamlineID23-1
Temperature [K]100
Detector technologyPIXEL
Collection date2017-05-18
DetectorDECTRIS PILATUS3 S 6M
Wavelength(s)0.972422
Spacegroup nameP 21 21 21
Unit cell lengths62.190, 62.670, 165.530
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution42.650 - 3.100
R-factor0.195
Rwork0.195
R-free0.23480
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHENIX
Refinement softwareBUSTER (2.10.2)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]44.1443.211
High resolution limit [Å]3.1003.100
Rmerge0.080
Number of reflections12300
<I/σ(I)>16.78
Completeness [%]100.0
Redundancy7.9
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP72900.5 M ammonium sulfate, 0.1 M PIPES pH7, 0.9 M disodium tartrate

218853

PDB entries from 2024-04-24

PDB statisticsPDBj update infoContact PDBjnumon