6FVS
The active form of a pentameric ion channel (sTeLIC) gated by alkaline pH - sTeLIC in complex with Barium ions (Ba2+)
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SOLEIL BEAMLINE PROXIMA 1 |
Synchrotron site | SOLEIL |
Beamline | PROXIMA 1 |
Temperature [K] | 193 |
Detector technology | PIXEL |
Collection date | 2016-12-06 |
Detector | PSI PILATUS 6M |
Wavelength(s) | 2.000 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 218.840, 112.110, 144.080 |
Unit cell angles | 90.00, 112.79, 90.00 |
Refinement procedure
Resolution | 20.000 - 3.200 |
R-factor | 0.209 |
Rwork | 0.208 |
R-free | 0.22600 |
RMSD bond length | 0.010 |
RMSD bond angle | 1.160 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | BUSTER (2.10.3) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 49.070 | 3.300 |
High resolution limit [Å] | 3.200 | 3.200 |
Number of reflections | 52251 | |
<I/σ(I)> | 9.1 | |
Completeness [%] | 98.4 | |
Redundancy | 3.2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | EVAPORATION | 292 | 150 mM MaCl2 20 mM tris 8.0 35% PEG 200 |