Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6FTD

Deinococcus radiodurans BphP PAS-GAF H290T mutant

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE MASSIF-3
Synchrotron siteESRF
BeamlineMASSIF-3
Temperature [K]100
Detector technologyPIXEL
Collection date2015-06-23
DetectorDECTRIS EIGER X 4M
Wavelength(s)0.96770
Spacegroup nameC 1 2 1
Unit cell lengths94.810, 53.030, 135.880
Unit cell angles90.00, 93.30, 90.00
Refinement procedure
Resolution47.330 - 1.400
R-factor0.15046
Rwork0.148
R-free0.19816
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)5k5b
RMSD bond length0.028
RMSD bond angle2.551
Data reduction softwareXDS (March 1, 2015)
Data scaling softwareXSCALE
Phasing softwarePHASER (2.5.7)
Refinement softwareREFMAC (5.8.0135)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]47.3301.440
High resolution limit [Å]1.4001.400
Rmerge0.1081.362
Rmeas0.1241.552
Number of reflections1323519607
<I/σ(I)>7.480.93
Completeness [%]99.799.5
Redundancy4.254.26
CC(1/2)0.9970.336
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP4.9529767 mM Sodium acetate, 3.3 % PEG400, 1mM DTT, 30% 2-methyl-2,4-pentanediol