Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6FPL

TETR(D) E147A MUTANT IN COMPLEX WITH TETRACYCLINE AND MAGNESIUM

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsBESSY BEAMLINE 14.2
Synchrotron siteBESSY
Beamline14.2
Temperature [K]100
Detector technologyCCD
Collection date2011-12-03
DetectorMARMOSAIC 225 mm CCD
Wavelength(s)0.95
Spacegroup nameI 41 2 2
Unit cell lengths68.020, 68.020, 179.030
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution63.590 - 1.602
R-factor0.18772
Rwork0.186
R-free0.22093
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2trt
RMSD bond length0.018
RMSD bond angle1.837
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0073)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]63.5901.644
High resolution limit [Å]1.6021.602
Rmerge0.047
Number of reflections281471959
<I/σ(I)>31.95
Completeness [%]94.596
Redundancy17.66
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6.5295Precipitant 0.1M Na-citrat, 0.8M Li2SO4, 0.5M (NH4)2SO4, 0.1mL Protein (10.19mg/ml, 0.1M MES pH 6.5) + 0.1mL 2mM Tc + 0.001mL 3M MgCl2 1:4 Precipitant/Protein

218853

PDB entries from 2024-04-24

PDB statisticsPDBj update infoContact PDBjnumon