Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6F39

C1r homodimer CUB1-EGF-CUB2

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I03
Synchrotron siteDiamond
BeamlineI03
Temperature [K]100
Detector technologyPIXEL
Collection date2017-07-09
DetectorDECTRIS PILATUS3 S 6M
Wavelength(s)0.976
Spacegroup nameC 1 2 1
Unit cell lengths140.563, 54.620, 138.180
Unit cell angles90.00, 99.90, 90.00
Refinement procedure
Resolution68.061 - 5.801
R-factor0.3096
Rwork0.308
R-free0.33790
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.010
RMSD bond angle1.357
Data reduction softwareMOSFLM
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (dev_2722)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]68.1006.000
High resolution limit [Å]5.8005.800
Rpim0.118
Number of reflections2987
<I/σ(I)>5.11.8
Completeness [%]99.8
Redundancy15.2
CC(1/2)0.997
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP29812-18% PEG 8000, 100 mM Imidazole at pH 8.0

224004

PDB entries from 2024-08-21

PDB statisticsPDBj update infoContact PDBjnumon