6F11
GLIC mutant D86A
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID29 |
Synchrotron site | ESRF |
Beamline | ID29 |
Temperature [K] | 190 |
Detector technology | PIXEL |
Collection date | 2015-10-04 |
Detector | DECTRIS PILATUS3 6M |
Wavelength(s) | 0.9780 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 181.820, 133.790, 160.160 |
Unit cell angles | 90.00, 102.29, 90.00 |
Refinement procedure
Resolution | 20.000 - 2.950 |
R-factor | 0.1961 |
Rwork | 0.195 |
R-free | 0.21550 |
RMSD bond length | 0.010 |
RMSD bond angle | 1.060 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | BUSTER (2.10.2) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 49.440 | 3.010 |
High resolution limit [Å] | 2.950 | 2.950 |
Number of reflections | 77611 | |
<I/σ(I)> | 10.9 | |
Completeness [%] | 99.9 | |
Redundancy | 7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | EVAPORATION | 293 | 100 mM NaAcetate pH4 400 mM NaSCN 12-15% PEG 4000 15% glycerol 3%DMSO |