6F0I
GLIC mutant E26A
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SOLEIL BEAMLINE PROXIMA 1 |
Synchrotron site | SOLEIL |
Beamline | PROXIMA 1 |
Temperature [K] | 190 |
Detector technology | PIXEL |
Collection date | 2015-05-06 |
Detector | DECTRIS PILATUS 6M-F |
Wavelength(s) | 0.98 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 181.067, 133.412, 159.241 |
Unit cell angles | 90.00, 102.14, 90.00 |
Refinement procedure
Resolution | 25.000 - 3.000 |
R-factor | 0.2087 |
Rwork | 0.208 |
R-free | 0.22260 |
RMSD bond length | 0.010 |
RMSD bond angle | 1.100 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | BUSTER (2.10.2) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 49.540 | 3.160 |
High resolution limit [Å] | 3.000 | 3.000 |
Number of reflections | 74072 | |
<I/σ(I)> | 11.4 | |
Completeness [%] | 99.8 | |
Redundancy | 3.9 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | EVAPORATION | 4 | 291.15 | PEG 4000, 15% Glycerol, 0.1M Sodium acetate, 0.4M Thiocyanate, 3% DMSO |