6EU6
Sensor Amt Protein
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06SA |
Synchrotron site | SLS |
Beamline | X06SA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2015-02-04 |
Detector | PSI PILATUS 6M |
Wavelength(s) | 1.000 |
Spacegroup name | P 63 |
Unit cell lengths | 99.745, 99.745, 89.069 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 86.380 - 1.980 |
R-factor | 0.15356 |
Rwork | 0.152 |
R-free | 0.18450 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2b2h |
RMSD bond length | 0.019 |
RMSD bond angle | 1.964 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | MOLREP |
Refinement software | REFMAC (5.8.0073) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 86.380 | 2.030 |
High resolution limit [Å] | 1.980 | 1.980 |
Rmerge | 0.112 | 1.461 |
Rpim | 0.037 | 0.469 |
Number of reflections | 33401 | 2466 |
<I/σ(I)> | 12.1 | |
Completeness [%] | 100.0 | 99.9 |
Redundancy | 10.3 | 10.5 |
CC(1/2) | 0.999 | 0.735 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7 | 293 | 0.1 M MES/NaOH pH 7.0 24 % (w/v) of polyethylene glycol 3350 |