6E4T
Structure of AMPK bound to activator
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 17-ID |
Synchrotron site | APS |
Beamline | 17-ID |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2013-06-02 |
Detector | DECTRIS PILATUS 6M-F |
Wavelength(s) | 1 |
Spacegroup name | P 61 2 2 |
Unit cell lengths | 123.610, 123.610, 402.550 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 30.010 - 3.400 |
R-factor | 0.218 |
Rwork | 0.216 |
R-free | 0.24500 |
RMSD bond length | 0.010 |
RMSD bond angle | 1.300 |
Data reduction software | autoXDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | BUSTER (2.11.7) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 30.010 | 3.520 |
High resolution limit [Å] | 3.400 | 3.400 |
Rmerge | 0.137 | 0.659 |
Number of reflections | 25978 | |
<I/σ(I)> | 11 | |
Completeness [%] | 99.9 | |
Redundancy | 5.2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 293 | 750 MM AMMONIUM SULFATE, 500 MM LITHIUM SULFATE, 100 MM TRISODIUM CITRATE, 1% ETHYLENE GLYCOL |